The advanced single-channel TDR capable of identifying and locating faults on metallic cables. The TDR is suitable for use on both dead or live cables.
The advanced single-channel TDR capable of identifying and locating faults on metallic cables. The TDR is suitable for use on both dead or live cables.
An AUTO selection option ensures that the most effective parameters are selected depending on the range required, aiding rapid diagnosis of the TDR trace. Dual cursors allow complete flexibility, giving the operator full control and instant indication of distance between two points.
A trace HOLD feature also allows comparison between the conditions, something not seen on most other handheld TDRs. Extra high resolution together with white-light backlight and grey scale tones give the graphical display a vibrancy, aiding the user in identifying key events on the trace.
Features
Ranges | 10 m, 25 m, 100 m, 250 m, 1000 m, 2500 m, 5000 m (30 ft, 75 ft, 300 ft, 750 ft, 3000 ft, 7500 ft, 15000 ft) |
Accuracy | ±1% of range ± pixel at 0.67 VF [Note- The measurement accuracy is for the indicated cursor position only and is conditional on the velocity factor being correct.] |
Resolution | 1% of range |
Refresh Rate | Trace updates 3 times per second |
Input Protection | This instrument complies with IEC61010-1 for connection to live systems up to 150 V CAT IV when used with the optional fused test lead set |
Output Pulse | 5 volts peak to peak into open circuit. Pulse widths determined by range and cable |
Grain | Set for each range with three user selectable steps (in manual operating mode) |
Velocity | Variable from 0.2 to 0.99 in steps of 0.01 |
TX Null | Automatic |
Power Down | Automatic after 5 minutes with no key press |
Backlight | Stays on for 1 minute with no key press |
Batteries | Five LR6 (AA) type batteries, Manganese alkali or nickel metal-hydride cell |
Battery Life | Up to 14 hours (Typical) |
Mechanical | Designed for indoors or outdoors and rated IP54 |
Case Dimensions | 230 mm (9 in) x 115 mm (4.5 inches) x 48 mm (2 inches) |
Instrument Weight | 0.6 kg |
Case Material | ABS |
Connectors | Two 4 mm-safety terminals |
Display | 256 x 128 pixel Graphics LCD |
Operating Temperature | -15 ºC to +50 ºC (5 ºF to 122 ºF) |
Click on a category to view a selection of compatible accessories with the Megger TDR1000/3P (1001-789) Single Channel L V Cable Fault Locator.
Ranges | 10 m, 25 m, 100 m, 250 m, 1000 m, 2500 m, 5000 m (30 ft, 75 ft, 300 ft, 750 ft, 3000 ft, 7500 ft, 15000 ft) |
Accuracy | ±1% of range ± pixel at 0.67 VF [Note- The measurement accuracy is for the indicated cursor position only and is conditional on the velocity factor being correct.] |
Resolution | 1% of range |
Refresh Rate | Trace updates 3 times per second |
Input Protection | This instrument complies with IEC61010-1 for connection to live systems up to 150 V CAT IV when used with the optional fused test lead set |
Output Pulse | 5 volts peak to peak into open circuit. Pulse widths determined by range and cable |
Grain | Set for each range with three user selectable steps (in manual operating mode) |
Velocity | Variable from 0.2 to 0.99 in steps of 0.01 |
TX Null | Automatic |
Power Down | Automatic after 5 minutes with no key press |
Backlight | Stays on for 1 minute with no key press |
Batteries | Five LR6 (AA) type batteries, Manganese alkali or nickel metal-hydride cell |
Battery Life | Up to 14 hours (Typical) |
Mechanical | Designed for indoors or outdoors and rated IP54 |
Case Dimensions | 230 mm (9 in) x 115 mm (4.5 inches) x 48 mm (2 inches) |
Instrument Weight | 0.6 kg |
Case Material | ABS |
Connectors | Two 4 mm-safety terminals |
Display | 256 x 128 pixel Graphics LCD |
Operating Temperature | -15 ºC to +50 ºC (5 ºF to 122 ºF) |
Click on a category to view a selection of compatible accessories with the Megger TDR1000/3P (1001-789) Single Channel L V Cable Fault Locator.