This high voltage insulation resistance tester is battery powered and designed for the maintenance and servicing of high voltage cables, rotating plant machinery, transformers, switchgear and industrial installations. Three insulation resistance (IR) test modes are provided, (InS, PI and T) and available in any IR test range.
This high voltage insulation resistance tester is battery powered and designed for the maintenance and servicing of high voltage cables, rotating plant machinery, transformers, switchgear and industrial installations. Three insulation resistance (IR) test modes are provided, (InS, PI and T) and available in any IR test range.
This battery powered insulation resistance tester is designed high voltage testing for the maintenance and servicing of cables, rotating plant machinery, transformers, switchgear and industrial installations. Automatic discharge for capacitive circuits under test is provided and decaying voltage is displayed. The BM5200 is powered by eight AA batteries and three insulation resistance (IR) test modes are provided.
Features
Applications
Insulation range | 100 kΩ to 1 TΩ |
Nominal test voltages | 250 V, 500 V, 1000 V, 2500 V, 5000 V |
Terminal voltage accuracy | < 1000 V 0...+10% of nominal test voltage
≥1000 V 0...+5% of nominal test voltage |
Insulation accuracy | Up to 1 GΩ: All ranges ±5% ±2 digits
Over 1 GΩ: 5000 V ±5% ±0.04% per GΩ 2500 V ±5% ±0.08% per GΩ 1000 V ±5% ±0.2% per GΩ 500 V ±5% ±0.4% per GΩ 250 V ±5% ±0.8% per GΩ |
Short circuit/charge current | 1.4 mA ±0.5 mA |
Maximum capacitance of load | 5 μF |
Voltmeter accuracy | 3% ± 3 V |
Frequency measurement | 45 Hz to 65 Hz |
Frequency measurement accuracy | ±2 Hz |
Voltmeter range | Up to 600 V a.c. or d.c. |
Power supply | 8 x LR6/AA batteries (included) |
Battery life | 5 lbs (2.3 kg) |
5 hours @ 5 kV into 100 MΩ with AA Alkaline LR6 | 5 lbs (2.3 kg) |
Guard | 2% error guarding 5 MΩ leakage on 100 MΩ load |
Operating temperature range and humidity | -20 to +55 °C |
Humidity | 90% RH, 0 to 40 °C
70% RH, 40 to 55 °C |
Storage temperature range | -20 to +65 °C |
IP rating | IP40 |
Safety protection | Insulation Cat III 600 V |
EMC | The product conforms to IEC 61326 |
Dimensions | 220 mm x 115 mm x 163 mm |
Weight | 1.45 kg |
Insulation range | 100 kΩ to 1 TΩ |
Nominal test voltages | 250 V, 500 V, 1000 V, 2500 V, 5000 V |
Terminal voltage accuracy | < 1000 V 0...+10% of nominal test voltage
≥1000 V 0...+5% of nominal test voltage |
Insulation accuracy | Up to 1 GΩ: All ranges ±5% ±2 digits
Over 1 GΩ: 5000 V ±5% ±0.04% per GΩ 2500 V ±5% ±0.08% per GΩ 1000 V ±5% ±0.2% per GΩ 500 V ±5% ±0.4% per GΩ 250 V ±5% ±0.8% per GΩ |
Short circuit/charge current | 1.4 mA ±0.5 mA |
Maximum capacitance of load | 5 μF |
Voltmeter accuracy | 3% ± 3 V |
Frequency measurement | 45 Hz to 65 Hz |
Frequency measurement accuracy | ±2 Hz |
Voltmeter range | Up to 600 V a.c. or d.c. |
Power supply | 8 x LR6/AA batteries (included) |
Battery life | 5 lbs (2.3 kg) |
5 hours @ 5 kV into 100 MΩ with AA Alkaline LR6 | 5 lbs (2.3 kg) |
Guard | 2% error guarding 5 MΩ leakage on 100 MΩ load |
Operating temperature range and humidity | -20 to +55 °C |
Humidity | 90% RH, 0 to 40 °C
70% RH, 40 to 55 °C |
Storage temperature range | -20 to +65 °C |
IP rating | IP40 |
Safety protection | Insulation Cat III 600 V |
EMC | The product conforms to IEC 61326 |
Dimensions | 220 mm x 115 mm x 163 mm |
Weight | 1.45 kg |