Compatible with the 5010, 5020, and 5050 loggers and 6300, 6305, 6310, and 6315 power meters, this clamp sensor provides easy and safe installations in existing facilities without errors. In addition, this load current detection type clamp sensor features a rated current of 5 A AC and fits conductors 0.9" (24 mm) in diameter.
Compatible with the 5010, 5020, and 5050 loggers and 6300, 6305, 6310, and 6315 power meters, this clamp sensor provides easy and safe installations in existing facilities without errors. In addition, this load current detection type clamp sensor features a rated current of 5 A AC and fits conductors 0.9" (24 mm) in diameter.
Rated Current | 5 A AC (maximum 50 A AC) |
Output Voltage | 50 mV/5 A AC [maximum 500 mV/50 A AC] (10 mV/A AC) |
Accuracy | ±0.5% rdg ±0.1 mV (50/60 Hz) ±1% rdg ±0.2 mV (40 Hz to 1 kHz) |
Phase Shift | Within ±2° (45 to 65 Hz) |
Output | Connector: MINI DIN 6-pin Impedance: Approximately 20 Ω |
Applicable Standards | IEC 61010-1, IEC 61010-2-032:2002 CAT III 300 V pollution degree 2, IEC 61326 |
Operating Temperature/Humidity Range | 32 to 122°F (0 to 50°C), less than 85% RH (without condensation) |
Conductor Size | Ø0.9" (Ø24 mm) |
Cable Length | Approximately 9.8' (3 m) |
Dimensions | 3.9 x 1.6 x 1" (100 x 60 x 26 mm) |
Weight | Approximately 5.6 oz (160 g) |