Use this meter to measure magnetic field exposure and magnetic flux density. The meter offers 3 axes from 10 Hz to 400 kHz of measurement.
Use this meter to measure magnetic field exposure and magnetic flux density. The meter offers 3 axes from 10 Hz to 400 kHz of measurement.
Designed for measurements of magnetic flux density and magnetic field exposure created by products manufactured at a customer site or produced by devices in a customer environment, this magnetic field tester comes bundled with two sensors.
Features
Applications
Magnetic Flux Density (Bandwidth) | 10 Hz to 400 kHz 10 Hz to 2 kHz 2k Hz to 400 kHz |
Magnetic Flux Density | Range: X, Y, Z axes: 2 μT to 2 mT in 4 ranges Accuracy: ±3.5% of reading ±0.5% of full scale Range: R Axis: 3.464 μT to 3.464 mT in 4 ranges Accuracy: ±3.5% of reading ±0.5% of full scale |
Exposure Level | General public/occupational Range: X, Y, Z axes: 20 to 200% in 2 ranges Accuracy: 50 Hz to 1 kHz: ±3.5% of reading ±0.5% of full scale Range: R axis: 34.64 to 346.4% in 2 ranges Accuracy: 1 to 100 kHz: ±5% of reading ±0.5% of full scale |
Indicated Axes | X, Y, Z/ R (measured axes: X, Y, Z) |
Measurement Method | True RMS |
Range Switching | Auto/manual |
Display Update Rate | Slow function off: 250 ms Slow function on: 2 s (Slow function: functionality for applying the 1-sec RMS value integration time required by IEC/EN 62233) |
Crest Factor | 3 or less Exposure level (occupational) for r1 is 1.45 or less |
Supporting Output Interface | Resultant RMS level Exposure level Waveform output of magnetic flux density X/ Y/ Z each axis 0.1 mV/display value count [USB 1.1] data saving with the PC application |
Power Supply | 4 x LR6 (AA) alkaline battery 0.8 VA (at battery operation) |
Other Functions | Memory, slow, maximum value hold, auto power off, buzzer sound on/off |
Temperature | Operating: 32 to 104°F (0 to 40°C), 80% RH or less (no condensation) Storage: 14 to 122°F (-10 to 50°C), 80% RH or less (no condensation) |
Continuous Usage | Approximately 10 h (with sensor connected, continuous, low load operation) |
Interface | USB1.1 |
Dimensions | 3.94 × 5.91 ×1.65" (100 × 150 × 42 mm) |
Weight | 30.7 oz (870g) |
Applicable Standards | Safety EN61010 EMC EN61326, EN61000-3-2, EN61000-3-3 |
Standard Compliance | IEC61786 |
Magnetic Flux Density (Bandwidth) | 10 Hz to 400 kHz 10 Hz to 2 kHz 2k Hz to 400 kHz |
Magnetic Flux Density | Range: X, Y, Z axes: 2 μT to 2 mT in 4 ranges Accuracy: ±3.5% of reading ±0.5% of full scale Range: R Axis: 3.464 μT to 3.464 mT in 4 ranges Accuracy: ±3.5% of reading ±0.5% of full scale |
Exposure Level | General public/occupational Range: X, Y, Z axes: 20 to 200% in 2 ranges Accuracy: 50 Hz to 1 kHz: ±3.5% of reading ±0.5% of full scale Range: R axis: 34.64 to 346.4% in 2 ranges Accuracy: 1 to 100 kHz: ±5% of reading ±0.5% of full scale |
Indicated Axes | X, Y, Z/ R (measured axes: X, Y, Z) |
Measurement Method | True RMS |
Range Switching | Auto/manual |
Display Update Rate | Slow function off: 250 ms Slow function on: 2 s (Slow function: functionality for applying the 1-sec RMS value integration time required by IEC/EN 62233) |
Crest Factor | 3 or less Exposure level (occupational) for r1 is 1.45 or less |
Supporting Output Interface | Resultant RMS level Exposure level Waveform output of magnetic flux density X/ Y/ Z each axis 0.1 mV/display value count [USB 1.1] data saving with the PC application |
Power Supply | 4 x LR6 (AA) alkaline battery 0.8 VA (at battery operation) |
Other Functions | Memory, slow, maximum value hold, auto power off, buzzer sound on/off |
Temperature | Operating: 32 to 104°F (0 to 40°C), 80% RH or less (no condensation) Storage: 14 to 122°F (-10 to 50°C), 80% RH or less (no condensation) |
Continuous Usage | Approximately 10 h (with sensor connected, continuous, low load operation) |
Interface | USB1.1 |
Dimensions | 3.94 × 5.91 ×1.65" (100 × 150 × 42 mm) |
Weight | 30.7 oz (870g) |
Applicable Standards | Safety EN61010 EMC EN61326, EN61000-3-2, EN61000-3-3 |
Standard Compliance | IEC61786 |