Hioki 3153 Automatic Insulation/Withstanding HiTester

Model: 3153

Hioki 3153 Automatic Insulation/Withstanding HiTester

Model: 3153

Designed for insulation resistance and voltage withstand testing of electrical devices and components according to various safety standards. A multitude of automation and labor-saving features are provided to ensure effective testing for a wide variety of requirements and test conditions. Select the most appropriate model for your applications.

Designed for insulation resistance and voltage withstand testing of electrical devices and components according to various safety standards. A multitude of automation and labor-saving features are provided to ensure effective testing for a wide variety of requirements and test conditions. Select the most appropriate model for your applications.

Sale Price $8349.89 CAD
Regular Price $10503.00 CAD
Availability 8 to 9 Weeks
Quantity

Hioki 3153 Offers

Programable testing, full remote control, Automatic Insulation Withstanding Tester This electrical safety test instrument series is designed for insulation resistance and voltage withstand testing of electrical devices and components according to various safety standards. A multitude of automation and labor-saving Features are provided to ensure effective testing for a wide variety of requirements and test conditions. Select the most appropriate model for your applications.

Features

  • Insulation and AC/DC continuous voltage withstand testing
  • Safety standards compliance testing
  • Stores up to 10 sets of test conditions (10 each for insulation and voltage withstand)
  • Zero-V Switching (voltage withstand testing)
  • Electrical Discharge function (DC voltage withstand, insulation testing)
  • Automated testing support
  • Interlock Protect function
  • Remote controllable

Hioki 3153 Specifications

Output voltage 0.20 to 5.00 kV
Voltage output method PWM switching method
Transformer capacity 500 VA (rated 30 minutes)
Output capacity 50 VA (continuous)
Voltage adjustment method Digital setting (0.01 kV setting resolution)
Output voltage accuracy ±1.5% of setting voltage ±2 dgt.
Voltage change rate AC: ±7% or less(max. 5 kV at 100 mA →unloaded: with resistive load)*2
DC: ±16% or less(max. 5 kV at10 mA → unloaded: with resistive load)*2
Voltage waveform Sine wave (5% or less distortion, unloaded)
Voltage frequency 50 or 60 Hz ±0.2%
Output ripple voltage 6% of output voltage or less (at 5 kV DC, 10 mA, resistive load)
Output current AC: 100 mA *1
DC:10 mA (continuous)
Voltmeter Digital: 0.00 to 5.00 kV (full scale) Accuracy: ±1.5% f.s.
Analog: 0 to 5 kV (full scale) Accuracy: ±5% f.s.
Current measurement range AC: 0.01 to 100.0 mA
DC: 0.01 to 10.0 mA
Indicated value range AC: 10 or 100 mA
DC: 10 mA
Measurement resolution 0.00 to 10.00 or 0.01 mA (10-mA range)
10.1 to 100.0 or 0.1 mA (100-mA range, AC only)
Current measurement accuracy ± (2% rdg. + 5 dgt.) common to each range *3
*1. Time vs. Output Voltage (at 23 ̊C ambient)
*2. Unloaded = 40 MΩ load (instrument input impedance)
*3. Plus scanner accuracy, when used.
Click here for complete specifications on the Hioki 3153

What's included with the Hioki 3153

  • Hioki 3153 Automatic Insulation/Withstanding HiTester

Ask a question about Hioki 3153 Automatic Insulation/Withstanding HiTester

Customer Reviews for the Hioki 3153

Hioki 3153 Offers

Programable testing, full remote control, Automatic Insulation Withstanding Tester This electrical safety test instrument series is designed for insulation resistance and voltage withstand testing of electrical devices and components according to various safety standards. A multitude of automation and labor-saving Features are provided to ensure effective testing for a wide variety of requirements and test conditions. Select the most appropriate model for your applications.

Features

  • Insulation and AC/DC continuous voltage withstand testing
  • Safety standards compliance testing
  • Stores up to 10 sets of test conditions (10 each for insulation and voltage withstand)
  • Zero-V Switching (voltage withstand testing)
  • Electrical Discharge function (DC voltage withstand, insulation testing)
  • Automated testing support
  • Interlock Protect function
  • Remote controllable

Hioki 3153 Specifications

Output voltage 0.20 to 5.00 kV
Voltage output method PWM switching method
Transformer capacity 500 VA (rated 30 minutes)
Output capacity 50 VA (continuous)
Voltage adjustment method Digital setting (0.01 kV setting resolution)
Output voltage accuracy ±1.5% of setting voltage ±2 dgt.
Voltage change rate AC: ±7% or less(max. 5 kV at 100 mA →unloaded: with resistive load)*2
DC: ±16% or less(max. 5 kV at10 mA → unloaded: with resistive load)*2
Voltage waveform Sine wave (5% or less distortion, unloaded)
Voltage frequency 50 or 60 Hz ±0.2%
Output ripple voltage 6% of output voltage or less (at 5 kV DC, 10 mA, resistive load)
Output current AC: 100 mA *1
DC:10 mA (continuous)
Voltmeter Digital: 0.00 to 5.00 kV (full scale) Accuracy: ±1.5% f.s.
Analog: 0 to 5 kV (full scale) Accuracy: ±5% f.s.
Current measurement range AC: 0.01 to 100.0 mA
DC: 0.01 to 10.0 mA
Indicated value range AC: 10 or 100 mA
DC: 10 mA
Measurement resolution 0.00 to 10.00 or 0.01 mA (10-mA range)
10.1 to 100.0 or 0.1 mA (100-mA range, AC only)
Current measurement accuracy ± (2% rdg. + 5 dgt.) common to each range *3
*1. Time vs. Output Voltage (at 23 ̊C ambient)
*2. Unloaded = 40 MΩ load (instrument input impedance)
*3. Plus scanner accuracy, when used.
Click here for complete specifications on the Hioki 3153

What's included with the Hioki 3153

  • Hioki 3153 Automatic Insulation/Withstanding HiTester

Ask a question about Hioki 3153 Automatic Insulation/Withstanding HiTester

Customer Reviews for the Hioki 3153

More Hioki Products