Featuring an accurate and easy to operate manometer that utilizes mobile technology to communicate via Bluetooth connection, to monitor differential pressure and flow to three different valves. Wireless transducers and a versatile handheld allow a single operator to monitor and balance a hydronic system in less time.

Featuring an accurate and easy to operate manometer that utilizes mobile technology to communicate via Bluetooth connection, to monitor differential pressure and flow to three different valves. Wireless transducers and a versatile handheld allow a single operator to monitor and balance a hydronic system in less time.

Sale Price $5019.21 CAD
Regular Price $5397.00 CAD
Availability 2 to 3 Weeks
Quantity

Dwyer 490W-6-HKIT Offers

Features

  • Rugged weatherproof handheld housing withstands 1.5 m drop test
  • Wireless measurement of differential pressure, single pressure and air flow
  • Share logged data directly from handheld over Wi-Fi, GSM or CDMA networks
  • Bluetooth direct wireless communication provides range up to 65' (19.8 m)
  • The ergonomic design is much lighter and easier to work with, providing greater maneuverability and quick install setup
  • Dwyer Hydronic Application Software

Applications

  • Refrigerant pressure testing
  • Hydronic valve balancing
  • Measure pressure drop across pumps
  • Measure pressure drop across chiller and coils for freeze protection

Dwyer 490W-6-HKIT Specifications

Wireless Distance Up to 65' (19.8 m)
Service Compatible gases and liquids
Wetted Materials 316 SS, PTFE, brass
Accuracy 2% of reading, ±1 psi
Compensated Temperature Range 14 to 140°F (-10 to 60°C)
Pressure Hysteresis ±0.25% FS
Pressure Limits 0 to 50 psi and 0 to 200 psi
Process Temperature Limits -4 to 185°F (-20 to 85°C)
Display 5" Gorrilla® glass 3, touch screen, 1280 x 720
Resolution 0.01 psi
Process Connections Two 1/4" male NPT
Power Requirements CR2050 lithium battery, user replaceable
Weight 2 lbs (907 g)
Agency Approvals CE, FCC
Click here for complete specifications on the Dwyer 490W-6-HKIT

What's included with the Dwyer 490W-6-HKIT

  • Wireless Hydronic Differential Pressure Manometer
  • Dwyer Hydronic App Preloaded onto Device
  • 4 x Pressure Transducers with Case
  • 2 x 1/4" SAE 45° x 1/4" Male NPT Straight Adapter
  • 2 x 1/4" Female Elbow x 1/4" Male NPT Fitting
  • Piercing Gauge Adapters:
    • 2 x 1/8" Diameter x 1-1/2" Length
    • 2 x 1/8" Diameter x 3" Length
    • 1/16 x 1-1/2" Length
  • 2 x Piercing Gauge Adapters and Fittings Case
  • Charger Cable and Power Adapter
  • Fabric Carrying Case
  • Installation and Operating Manual

Dwyer Wireless Hydronic Balancing Kit: Overview


In this video, the view will receive an overview of this wireless hydronic balancing kit. Additionally, it will go over the applications, how it works, features, and the included accessories.

How To Operate the Dwyer Hydronic App


This video will serve as a tutorial on how to operate the Dwyer hydronic app. Additionally, communicate via Bluetooth connection, to monitor differential pressure and flow to three different valves.

Click on a category to view a selection of compatible accessories with the Dwyer 490W-6-HKIT Hydronic Differential Pressure Manometer with Wireless Sensors.

Dwyer A-490W-3 Replacement Sensors for the 490W-6-HKIT, 0 to 50 psid A-490W-3
Includes two 0 to 50 psid replacement sensors for the 490W-6-HKIT Hydronic Differential Pressure Manometer.




Dwyer A-490W-4 Replacement Sensors for the 490W-6-HKIT, 0 to 100 psid A-490W-4
Includes two 0 to 100 psid replacement sensors for the 490W-6-HKIT Hydronic Differential Pressure Manometer.




Dwyer A-490W-5 Replacement Sensors for the 490W-6-HKIT, 0 to 500 psid A-490W-5
Includes two 0 to 500 psid replacement sensors for the 490W-6-HKIT Hydronic Differential Pressure Manometer.




Dwyer A-490W-6 Replacement Sensors for the 490W-6-HKIT, 0 to 200 psid A-490W-6
Includes two 0 to 200 psid replacement sensors for the 490W-6-HKIT Hydronic Differential Pressure Manometer.




Dwyer A-HKIT-500 Pressure Test Plug Adaptor for the 490W-6-HKIT, 1/8 x 1.5" A-HKIT-500
Includes two 1/8" diameter x 1.5" length adaptors for the 490W-6-HKIT Hydronic Differential Pressure Manometer.




Dwyer A-HKIT-500XL Pressure Test Plug Adaptor for the 490W-6-HKIT, 1/8 x 3" A-HKIT-500XL
Includes two 1/8" diameter x 3" length adaptors for the 490W-6-HKIT Hydronic Differential Pressure Manometer.




Dwyer A-HKIT-510 Pressure Test Plug Adaptor for the 490W-6-HKIT, 1/16 x 1.5" A-HKIT-510
Includes 1/16" diameter x 1.5" length adaptors for the 490W-6-HKIT Hydronic Differential Pressure Manometer.




Ask a question about Dwyer 490W-6-HKIT Hydronic Differential Pressure Manometer with Wireless Sensors

Customer Reviews for the Dwyer 490W-6-HKIT

Dwyer 490W-6-HKIT Offers

Features

  • Rugged weatherproof handheld housing withstands 1.5 m drop test
  • Wireless measurement of differential pressure, single pressure and air flow
  • Share logged data directly from handheld over Wi-Fi, GSM or CDMA networks
  • Bluetooth direct wireless communication provides range up to 65' (19.8 m)
  • The ergonomic design is much lighter and easier to work with, providing greater maneuverability and quick install setup
  • Dwyer Hydronic Application Software

Applications

  • Refrigerant pressure testing
  • Hydronic valve balancing
  • Measure pressure drop across pumps
  • Measure pressure drop across chiller and coils for freeze protection

Dwyer 490W-6-HKIT Specifications

Wireless Distance Up to 65' (19.8 m)
Service Compatible gases and liquids
Wetted Materials 316 SS, PTFE, brass
Accuracy 2% of reading, ±1 psi
Compensated Temperature Range 14 to 140°F (-10 to 60°C)
Pressure Hysteresis ±0.25% FS
Pressure Limits 0 to 50 psi and 0 to 200 psi
Process Temperature Limits -4 to 185°F (-20 to 85°C)
Display 5" Gorrilla® glass 3, touch screen, 1280 x 720
Resolution 0.01 psi
Process Connections Two 1/4" male NPT
Power Requirements CR2050 lithium battery, user replaceable
Weight 2 lbs (907 g)
Agency Approvals CE, FCC
Click here for complete specifications on the Dwyer 490W-6-HKIT

What's included with the Dwyer 490W-6-HKIT

  • Wireless Hydronic Differential Pressure Manometer
  • Dwyer Hydronic App Preloaded onto Device
  • 4 x Pressure Transducers with Case
  • 2 x 1/4" SAE 45° x 1/4" Male NPT Straight Adapter
  • 2 x 1/4" Female Elbow x 1/4" Male NPT Fitting
  • Piercing Gauge Adapters:
    • 2 x 1/8" Diameter x 1-1/2" Length
    • 2 x 1/8" Diameter x 3" Length
    • 1/16 x 1-1/2" Length
  • 2 x Piercing Gauge Adapters and Fittings Case
  • Charger Cable and Power Adapter
  • Fabric Carrying Case
  • Installation and Operating Manual

Dwyer Wireless Hydronic Balancing Kit: Overview


In this video, the view will receive an overview of this wireless hydronic balancing kit. Additionally, it will go over the applications, how it works, features, and the included accessories.

How To Operate the Dwyer Hydronic App


This video will serve as a tutorial on how to operate the Dwyer hydronic app. Additionally, communicate via Bluetooth connection, to monitor differential pressure and flow to three different valves.

Click on a category to view a selection of compatible accessories with the Dwyer 490W-6-HKIT Hydronic Differential Pressure Manometer with Wireless Sensors.

Dwyer A-490W-3 Replacement Sensors for the 490W-6-HKIT, 0 to 50 psid A-490W-3
Includes two 0 to 50 psid replacement sensors for the 490W-6-HKIT Hydronic Differential Pressure Manometer.




Dwyer A-490W-4 Replacement Sensors for the 490W-6-HKIT, 0 to 100 psid A-490W-4
Includes two 0 to 100 psid replacement sensors for the 490W-6-HKIT Hydronic Differential Pressure Manometer.




Dwyer A-490W-5 Replacement Sensors for the 490W-6-HKIT, 0 to 500 psid A-490W-5
Includes two 0 to 500 psid replacement sensors for the 490W-6-HKIT Hydronic Differential Pressure Manometer.




Dwyer A-490W-6 Replacement Sensors for the 490W-6-HKIT, 0 to 200 psid A-490W-6
Includes two 0 to 200 psid replacement sensors for the 490W-6-HKIT Hydronic Differential Pressure Manometer.




Dwyer A-HKIT-500 Pressure Test Plug Adaptor for the 490W-6-HKIT, 1/8 x 1.5" A-HKIT-500
Includes two 1/8" diameter x 1.5" length adaptors for the 490W-6-HKIT Hydronic Differential Pressure Manometer.




Dwyer A-HKIT-500XL Pressure Test Plug Adaptor for the 490W-6-HKIT, 1/8 x 3" A-HKIT-500XL
Includes two 1/8" diameter x 3" length adaptors for the 490W-6-HKIT Hydronic Differential Pressure Manometer.




Dwyer A-HKIT-510 Pressure Test Plug Adaptor for the 490W-6-HKIT, 1/16 x 1.5" A-HKIT-510
Includes 1/16" diameter x 1.5" length adaptors for the 490W-6-HKIT Hydronic Differential Pressure Manometer.




Ask a question about Dwyer 490W-6-HKIT Hydronic Differential Pressure Manometer with Wireless Sensors

Customer Reviews for the Dwyer 490W-6-HKIT

More Dwyer Products