Designed to make work easier, this DC power supply is laboratory grade and provides high current output in a compact, lightweight package. In addition, it features constant voltage (CV) and constant current (CC) modes, as preset and remote control modes. Save up to three presets of voltage and current values for quick recall.
Designed to make work easier, this DC power supply is laboratory grade and provides high current output in a compact, lightweight package. In addition, it features constant voltage (CV) and constant current (CC) modes, as preset and remote control modes. Save up to three presets of voltage and current values for quick recall.
Features
Applications
Output | Variable output voltage: 1 to 60 V Variable output current: 0 to 5 A |
Regulation | Voltage: Load (0 to 100% load): ≤50 mV Line (90 to 132 V AC, 170 to 264 V AC variation): ≤20 mV Current: Load (10 to 90% rated voltage): ≤100 mA Line (90 to 132 V AC, 170 to 264 V AC variation): ≤50 mA |
Ripple and Noise | Voltage (RMS): ≤5 mV Voltage (peak-peak): ≤50 mV Current (RMS): ≤30 mA |
Meter Type and Accuracy | 3-digit LED display ±0.2% + 3 counts |
Input Voltage | 100 to 240 V AC 50/60 Hz |
Full Load Input Current | 3.7 A (100 V AC) 1.7 A (230 V AC) |
Efficiency | 82% (100 V AC) 86% (230 V AC) |
Switching Frequency | 100 to 120 kHz |
Tracking Overvoltage Protections | O/P 1 to 5 V: set voltage +2 V O/P 5 to 20 V: set voltage +3 V O/P 20 to 60 V: set voltage +4 V |
Transient Response Time (50 to 100% Load) |
1.5 ms |
Power Factor Correction | >0.95 at optimal load |
Cooling Method | Thermostatically controlled fan from zero to full speed |
External Timed Programming | Maximum 20 voltage and current steps Maximum 99 minutes + 59 seconds step time Maximum 999 running cycles |
Temperature | Operating: 32 to 104°F (0 to 40°C) ≤80% RH Storage: 5 to 158°F (-15 to 70°C) ≤85% RH |
Dimensions | 7.9 x 3.5 x 8.2" (200 x 90 x 208 mm) |
Weight | 5.2 lbs (2.4 kg) |
Output | Variable output voltage: 1 to 60 V Variable output current: 0 to 5 A |
Regulation | Voltage: Load (0 to 100% load): ≤50 mV Line (90 to 132 V AC, 170 to 264 V AC variation): ≤20 mV Current: Load (10 to 90% rated voltage): ≤100 mA Line (90 to 132 V AC, 170 to 264 V AC variation): ≤50 mA |
Ripple and Noise | Voltage (RMS): ≤5 mV Voltage (peak-peak): ≤50 mV Current (RMS): ≤30 mA |
Meter Type and Accuracy | 3-digit LED display ±0.2% + 3 counts |
Input Voltage | 100 to 240 V AC 50/60 Hz |
Full Load Input Current | 3.7 A (100 V AC) 1.7 A (230 V AC) |
Efficiency | 82% (100 V AC) 86% (230 V AC) |
Switching Frequency | 100 to 120 kHz |
Tracking Overvoltage Protections | O/P 1 to 5 V: set voltage +2 V O/P 5 to 20 V: set voltage +3 V O/P 20 to 60 V: set voltage +4 V |
Transient Response Time (50 to 100% Load) |
1.5 ms |
Power Factor Correction | >0.95 at optimal load |
Cooling Method | Thermostatically controlled fan from zero to full speed |
External Timed Programming | Maximum 20 voltage and current steps Maximum 99 minutes + 59 seconds step time Maximum 999 running cycles |
Temperature | Operating: 32 to 104°F (0 to 40°C) ≤80% RH Storage: 5 to 158°F (-15 to 70°C) ≤85% RH |
Dimensions | 7.9 x 3.5 x 8.2" (200 x 90 x 208 mm) |